mirror of
https://github.com/Stichting-MINIX-Research-Foundation/u-boot.git
synced 2025-08-12 00:07:00 -04:00

When the LM75 temperature sensor measures a temperature below 0 C, the current driver does not perform sign extension, so the result returned is 256 C too high. This patch fixes the problem. Signed-off-by: Larry Johnson <lrj@acm.org>